Cqr Fp2 Installation Manual
Important note: This solution requires a Hotspot Operator Account at HotSpotSystem.com. You can create an Operator Account here. If you would like to see what features you will be able to use with our solutions, click here. If you already have an Operator Account, then read on..
The FP3 is a resettable and frangible combination EN54-11 compliant manual call. The United Kingdom by CQR. With jumpers to minimise installation errors.
1. Download the Java installer program:
http://coova-ap.s3.amazonaws.com/desktop/coova-ap.jnlp
2. Run this program and choose Flash CoovaAP.
3. Selet your device from the list and click save firmware to save the firmware image on your local drive.
4. If you re using a Ubiquiti device you should put it in TFTP mode by unplugging the POE ethernet cable, and reconnecting it while holding the reset button for 8 seconds. If this doesnt work, you may have to press it for 16 seconds. The LED lights now should flash alternately indicating TFTP mode.
5. Connect your router to the PC and open a command prompt. (cmd.exe)
FTP the image to the router using 'tftp -i 192.168.1.1 PUT code.bin code.bin'
6. After a succesful transfer you can restart the device. Unplug and plug the POE ethernet cable back in.
7. Go back to the Java installer program. After your router reboots, the 'Configure CoovaAP' button should now be available. Your PC should be set to the same network (192.168.1.X) in order for the program to see the router. Click the 'Configure CoovaAP' button and a browser window will pop up which will take you to your router.
Generac Installation Manual
8. After a mandatory password change you are ready to configure the hotspot.
Click Hotspot and select Settings. Use the following configuration:
Hotspot type should be CoovaChilli (other)
UAM Hostname: hotspotsystem.com
UAM secret: hotsys123
NAS Identifier: YOUROPERATORID_LOCATIONNUMBER
Login-page URL format: https://customer.hotspotsystem.com/customer/hotspotlogin.php
Splash-page URL format:
https://customer.hotspotsystem.com/customer/index.php?operator=YOUROPERATORID&location=LOCATIONNUMBER
9. It is suggested that you add the following domains to the walled garden hosts & ports:
a1.hotspotsystem.com through a20.hotspotsystem.com
In the walled garden dns domains enter the folowing:
hotspotsystem.com, worldpay.com, paypal.com, paypalobjects.com, paypal.112.2o7.net, adyen.com
10. Click DHCP
DHCP Server settings should be as on the photo below
Lan IP address: 192.168.182.1
Lan network: 192.168.182.0
Lan netmask: 255.255.255.0
DNS server 1 and 2: You can use your ISP's DNS server, or Google's free servers of 8.8.8.8 and 8.8.4.4
11. Radius tab
Primary Server: radius.hotspotsystem.com
Secondary Server: radius2.hotspotsystem.com
Auth Port: 1812
ACCT Port: 1813
Shared secret: hotsys123
AAA method: select radius
Leave all advanced option unchecked
12. After you save the settings Click Commit only and go back to the hotspot/status tab.
Click start Hotspot
Fox Blocks Installation Manual
You can now connect to the SSID (can be chagned under the wireless tab) and you shoudl receive an IP address on the 192.168.182.0 network. When connecting to an internet site you should get the splash page.
13. Add a cron to have device show up in the control center and get status email alerts.
To add a cron enter: crontab -e, and enter the following line (it should start with a number between 0-60):
0 /usr/bin/wget http://tech.hotspotsystem.com/up.php?mac=MACADDRESS&nasid=YOUROPERATORID_YOURLOCATIONID& uptime=`uptime sed s/' '/%20/g sed s/:/%3A/g sed s/,/%2C/g` -O /tmp/up.html
That's all. Currently you can only setup the hotspot on Wi-Fi. In a later version, it may be possible to setup the hotspot on bothe LAN + Wi-Fi.
If you have successfully setup your router you have to see a login window when connecting via wireless. You can log in with username admin, blank password.
Published on
10-Sep-2015View
44Download
5
DESCRIPTION
Eltek
Transcript
www.eltekenergy.com I www.flatpack2.com
Flatpack2 48/2000 Switch Mode Power Supply 48VDC
Key Features
Highest efficiency in minimum space Resonant topology makes the module efficiency industry
leading and contributes to the rectifiers ultra compact
dimensions.
Digital controllers Primary and secondary controls are digitalized, enabling
excellent monitoring and regulation characteristics.
Thus, the number of component has been reduced by
40% - for highly reliable, long life, trouble free DC
power systems.
Heat management Front-to-back air flow with chassis-integrated heat sinks
gives the module the most suitable working
environment and no limitations in the scalability of the
desired system solution.
Unique connection
A true plug-and-play connection system: time-to-install
and cost-reducing solution.
Global approvals Flatpack2 is CE marked, UL recognized and NEBS
certified for world wide installation.
Product Description
The Flatpack2 is a battery charger and rectifier for
stand-alone use or for working in parallel as part of a
DC power system controlled and monitored by the
Smartpack.
Flatpack2 is optimized for a wide range of system sizes.
Digital communication over CAN bus with Smartpack
simplifies system design and enhances flexibility.
Realization of Flatpack2 systems is possible by fitting 5
rectifiers across a 23 shelf and 4 rectifiers across a 19
shelf.
Applications
Wireless, fiber and fixed line communication
Todays communications demand state of the art, cost
efficient and compact DC power systems. Flatpack2
delivers the industry leading power density of 22W/in3
and superb reliability at lowest lifetime cost.
Broadband and network access
Increasing network speed demands flexible and
expandable DC power solutions. Flatpack2 is your key
building block for future needs.
Flatpack2 Switch Mode Power Supply 48VDC
109.00
41.5
0
327.22
(coming up)
109 mm 327 mm
41,5
mm
Location Company Telephone Fax Europe Eltek Energy AS +47 32 20 32 00 +47 32 20 32 10 Americas Eltek Energy, LLC +1 815 459 9100 +1 815 459 9118 Asia/Pacific Eltek Energy Pte Ltd. +65 6 7732326 +65 6 7753602 China Eltek Energy Ltd. +852 28982689 +852 28983189 Middle East Eltek Middle East +971 4 887 1176 +971 4 887 1175
www.eltekenergy.com I www.flatpack2.com
Flatpack2 Additional Technical Specifications AC Input
Voltage 85-300 VAC (Nominal 185 275 VAC)
Frequency 45 to 66Hz
Maximum Current
12.5 Arms maximum at nominal input and full load
Power Factor > 0.99 at 20% load or more
Input Protection Varistors for transient protection Mains fuse in both lines Disconnect above 300 VAC
DC Output Voltage 53.5 VDC (adj. range: 43.5-57.6 VDC)
Output Power 2000 W at nominal input
Maximum Current 41.7 Amps at 48 VDC and nominal input
Current Sharing 3% from true average current between modules
Static voltage regulation
0.5% from 10% to 100% load
Dynamic voltage regulation
5.0% for 10-90% or 90-10% load variation, regulation time < 50ms
Hold up time > 20ms; output voltage > 43.5 VDC at 1500W load
Ripple and Noise < 100 mV peak to peak, 30 MHz bandwith < 0.96 mV rms psophometric
Output Protection Overvoltage shutdown Blocking diode Short circuit proof High temperature protection
Other Specifications Efficiency Typical 92%, min. 91% at 40-90% load
Isolation 3.0 KVAC input and output 1.5 KVAC input earth 0.5 KVDC output earth
Alarms: Warnings:
Low mains shutdown High temperature shutdown Rectifier Failure Overvoltage shutdown on output Fan failure, one or two fans. Low voltage alarm at 43.5V CAN bus failure Low temperature shutdown Rectifier in power derate mode Remote battery current limit activated Input voltage out of range, flashing at overvoltage Loss of CAN communication with control unit, stand alone mode
Visual indications
Green LED: ON, no faults Red LED: rectifier failure Yellow LED : rectifier warning
Operating temp
-40 to +75C (-40 to +158F)
Storage temp -40 to +85C (-40 to +185F)
Cooling 2 fans (front to back airflow)
Fan Speed Temperature and current regulated
MTBF > 350, 000 hours Telcordia SR-332 Issue I, method III (a) (Tambient : 25C)
Acoustic Noise < 55dBA at nominal input and full load (Tambient < 30C)
Humidity Operating: 5% to 95% RH non-condensing Storage: 0% to 99% RH non-condensing
Dimensions 109 x 41.5 x 327mm (wxhxd) (4.25 x 1.69 x 13)
Weight 1.9 kg (4.19lbs)
Applicable standards Electrical safety IEC 60950-1
UL 60950-1 CSA 22.2
EMC ETSI EN 300 386 V.1.3.2 (telecommunication network) EN 61000-6-1 (immunity, light industry) EN 61000-6-2 (immunity, industry) EN 61000-6-3 (emission, light industry) EN 61000-6-4 (emission, industry) Telcordia NEBS GR1089 CORE
Harmonics EN 61000-3-2
Environment ETSI EN 300 019-2 (-1, -2, -3) ETSI EN 300 132-2 Telcordia NEBS GR63 CORE Zone 4 RoHS compliant (pending)
Specifications are subject to change without notice. ORDERING INFORMATION
Part no. Description
241115.100 Flatpack2 48/2000
Document Rev. No.: 241115.100.DS3 v.02