www.eltekenergy.com I www.flatpack2.com
Flatpack2 48/2000 Switch Mode Power Supply 48VDC
Key Features
Highest efficiency in minimum space Resonant topology makes the module efficiency industry
leading and contributes to the rectifiers ultra compact
dimensions.
Digital controllers Primary and secondary controls are digitalized, enabling
excellent monitoring and regulation characteristics.
Thus, the number of component has been reduced by
40% - for highly reliable, long life, trouble free DC
power systems.
Heat management Front-to-back air flow with chassis-integrated heat sinks
gives the module the most suitable working
environment and no limitations in the scalability of the
desired system solution.
Unique connection
A true plug-and-play connection system: time-to-install
and cost-reducing solution.
Global approvals Flatpack2 is CE marked, UL recognized and NEBS
certified for world wide installation.
Product Description
The Flatpack2 is a battery charger and rectifier for
stand-alone use or for working in parallel as part of a
DC power system controlled and monitored by the
Smartpack.
Flatpack2 is optimized for a wide range of system sizes.
Digital communication over CAN bus with Smartpack
simplifies system design and enhances flexibility.
Realization of Flatpack2 systems is possible by fitting 5
rectifiers across a 23 shelf and 4 rectifiers across a 19
shelf.
Applications
Wireless, fiber and fixed line communication
Todays communications demand state of the art, cost
efficient and compact DC power systems. Flatpack2
delivers the industry leading power density of 22W/in3
and superb reliability at lowest lifetime cost.
Broadband and network access
Increasing network speed demands flexible and
expandable DC power solutions. Flatpack2 is your key
building block for future needs.
Flatpack2 Switch Mode Power Supply 48VDC
109.00
41.5
0
327.22
(coming up)
109 mm 327 mm
41,5
mm
Location Company Telephone Fax Europe Eltek Energy AS +47 32 20 32 00 +47 32 20 32 10 Americas Eltek Energy, LLC +1 815 459 9100 +1 815 459 9118 Asia/Pacific Eltek Energy Pte Ltd. +65 6 7732326 +65 6 7753602 China Eltek Energy Ltd. +852 28982689 +852 28983189 Middle East Eltek Middle East +971 4 887 1176 +971 4 887 1175
www.eltekenergy.com I www.flatpack2.com
Flatpack2 Additional Technical Specifications AC Input
Voltage 85-300 VAC (Nominal 185 275 VAC)
Frequency 45 to 66Hz
Maximum Current
12.5 Arms maximum at nominal input and full load
Power Factor > 0.99 at 20% load or more
Input Protection Varistors for transient protection Mains fuse in both lines Disconnect above 300 VAC
DC Output Voltage 53.5 VDC (adj. range: 43.5-57.6 VDC)
Output Power 2000 W at nominal input
Maximum Current 41.7 Amps at 48 VDC and nominal input
Current Sharing 3% from true average current between modules
Static voltage regulation
0.5% from 10% to 100% load
Dynamic voltage regulation
5.0% for 10-90% or 90-10% load variation, regulation time < 50ms
Hold up time > 20ms; output voltage > 43.5 VDC at 1500W load
Ripple and Noise < 100 mV peak to peak, 30 MHz bandwith < 0.96 mV rms psophometric
Output Protection Overvoltage shutdown Blocking diode Short circuit proof High temperature protection
Other Specifications Efficiency Typical 92%, min. 91% at 40-90% load
Isolation 3.0 KVAC input and output 1.5 KVAC input earth 0.5 KVDC output earth
Alarms: Warnings:
Low mains shutdown High temperature shutdown Rectifier Failure Overvoltage shutdown on output Fan failure, one or two fans. Low voltage alarm at 43.5V CAN bus failure Low temperature shutdown Rectifier in power derate mode Remote battery current limit activated Input voltage out of range, flashing at overvoltage Loss of CAN communication with control unit, stand alone mode
Visual indications
Green LED: ON, no faults Red LED: rectifier failure Yellow LED : rectifier warning
Operating temp
-40 to +75C (-40 to +158F)
Storage temp -40 to +85C (-40 to +185F)
Cooling 2 fans (front to back airflow)
Fan Speed Temperature and current regulated
MTBF > 350, 000 hours Telcordia SR-332 Issue I, method III (a) (Tambient : 25C)
Acoustic Noise < 55dBA at nominal input and full load (Tambient < 30C)
Humidity Operating: 5% to 95% RH non-condensing Storage: 0% to 99% RH non-condensing
Dimensions 109 x 41.5 x 327mm (wxhxd) (4.25 x 1.69 x 13)
Weight 1.9 kg (4.19lbs)
Applicable standards Electrical safety IEC 60950-1
UL 60950-1 CSA 22.2
EMC ETSI EN 300 386 V.1.3.2 (telecommunication network) EN 61000-6-1 (immunity, light industry) EN 61000-6-2 (immunity, industry) EN 61000-6-3 (emission, light industry) EN 61000-6-4 (emission, industry) Telcordia NEBS GR1089 CORE
Harmonics EN 61000-3-2
Environment ETSI EN 300 019-2 (-1, -2, -3) ETSI EN 300 132-2 Telcordia NEBS GR63 CORE Zone 4 RoHS compliant (pending)
Specifications are subject to change without notice. ORDERING INFORMATION
Part no. Description
241115.100 Flatpack2 48/2000
Document Rev. No.: 241115.100.DS3 v.02
Installation Manual
Advertisement
Related Manuals for Aquafilter FP2
CQR FP2-GR-EDR. Fully key resettable red manual fire call point which offers almost. • Simple and quick installation • Suitable for a single.
Honeywell 6000 Installation Manual
Summary of Contents for Aquafilter FP2
Fox Blocks Installation Manual
Page 1: Installation Manual
Installation Manual...- Page 2 ® ® Use only genuine Aqua Market and Aquafilter replacement parts, filter cartridges and membrane elements. In case of use of other manufacturers' parts, Aquafilter is not responsible for any damages caused in the course of product use. 2. Technical Specifications Inlet water temperature......................between + 2 C (+ 35 F) and + 45 C (113 F)
- Page 3 FP2, FP3-2, FP3-K1, FP3-HJ-K1, FP3-3, FP3-4, FP3-5 the element is a part of the system: FP2, FP3-2, FP3-3, FP3-4, FP3-5 the element is a part of the system: FP3-K1, FP3-HJ-K1 the element is a part of the system: FP3-2...
- Page 4 4. Connecting Flexible Tubing with Quick Connectors: JG (John Guest) and QC (Quick Connector) Disconnect Flexible Tubing: 1) Remove safety clip from the quick connector (if applicable) (Fig. 1). 2) Press on the flange of quick connector (Fig. 2). 3) Pull out flexible tubing (Fig. 3). Connect Flexible Tubing: 1) Push the flexible tubing 1.5 cm (0.6 in) deep into the quick connector (Fig.
- Page 5 5. Preparing systems FP3-2, FP3-K1, FP3-HJ-K1, FP2, FP3-3, FP3-4, FP3-5 for installation Cartridge configuration for individual systems - refer to Table 1. Position the O-ring into the socket of filter head. Stretch Before placing the O-ring inside filter head, apply white o-ring properly and carefully arrange it in the socket cosmetic Vaseline to it.
- Page 6 FP3-2 FP3-K1 FP3-3 FP3-HJ-K1 FP3-4 FP3-5 Housing 1 FCPS5-AQM FCPS20 FCPS5 FCPS5-AQM FCPS5 FCPS5-AQM FCPS5-AQM Housing 2 FCCBL-AQM FCCBL FCCST2 FCCST-AQM FCCST2 FCCST-AQM FCCST-AQM Housing 3 FCPS5 FCCBKDF FCCBL-AQM FCCBKDF FCCBL-AQM FCCBL-AQM In-line filter cartridge 1 TLCHF-2T TLCHF-FP TLCHF-FP In-line filter cartridge 2 AIFIR1000 Table 1.
- Page 7 5.2 . Preparing FP3-4 system for installation: UF membrane installation Prior to system installation, first install a hollow fiber membrane: Remove plug-in from the inlet connector and UF membrane Use tubing to connect filtration system (start from elbow outlet. OUT) with UF membrane. WARNING! UF membrane is soaked with a special conserving solution.
- Page 8 6. System Installation - Stage I WARNING! Manufacturer is not responsible for any damages that result from improper installation or use of system. System installation should be performed only in temperatures above 2°C (35.6°F). Shut off cold water supply valve. Unscrew flexible tubing from the shut-off valve (or the adapter).
- Page 9 6.1. System Installation Option II - Wall Faucet Shut off water supply valve. Unscrew sink faucet from the wall. Screw chrome-plated adapter FT07 onto cold water pipe to Wind a few layers of Teflon Tape TAS0003 on shut-off valve allow easy SEWBV1414 valve installation and its easy adapter SEWBV 1414.
- Page 10 (all the way) into the faucet extension [4] and tighten it (by hand!) with the metal nut [10]. System FP2, FP3-2, FP3-K1, FP3-3 6) Push other end of flexible tubing with (OUT) elbow of the system.
- Page 11 8. Filtration Cartridges Description / Filtration Stage Longevity* Dimensions Cartridge Type PS20 Sediment, cold water cartridge for 10” housing. Designed for pre- filtration of tap and general-use water prior to the main filtration process. Cartridge stops sand, rust particles, sediments and impurities 9 7/8”...
- Page 12 Cartridge replacement in the following systems: FP2, FP3-2, FP3-3, FP3-K1, FP3-HJ-K1, FP3-4, FP3-5 Close your water supply valve. Open faucet valve to release Unscrew filter housing sump from filter cap by hand or using pressure build-up in the system. wrench (FXWR1-BL). (Remember to use wrench perpendicularly to the filter housing).
- Page 13 10. UF membrane replacement: FP3-4 Shut off water supply valve. Open filter faucet to release pressure from the system. Push in the flange and pull out flexible tubing. Remove UF membrane housing from mounting clips. Unscrew inlet and out let connectors from the UF Remove all layers of old Teflon tape and apply mutliply membrane.
- Page 14 Push in membrane housing into mouting clips. Insert flexible tubing (all the way) into both ends of UF WARNING! While installing UF membrane, remember to membrane. keep the proper direction of water flow (indicated by an NOTE ! Check if inlet/outlet tubings are correctly and arrow on membrane sticker).
- Page 15 Unscrew inlet and out let connectors from the membrane. Remove all layers of old Teflon tape and apply mutliply layers of new one. NOTE! Ensure that Telflon tape is winded in the opposite direction to the direction connector will be installed.
- Page 16 10.2. Replacing UF membrane and filter cartridge AIFIR1000 in FP3-5 system Disconnecting UF membrane and filter cartridge AIFIR1000 Shut off water supply valve. Open filter faucet to release from the system. First, disconnect tubing from the inlet pressure build-up in the filter. connector attached to hollow fiber membrane.
- Page 17 Unpack UF membrane and remove plug-ins. Screw-in connectors into new UF membrane housing. CAUTION! Don't backtrack during screwing in the connectors. Backtracking connectors may result in compromising the connection seal and water leaks. Unpack new filter cartridge AIFIR1000 and remove plug-ins Move mounting clips from old to the new filter cartridge from the inlet and outlet.
- Page 18 Connecting filter cartridge AIFIR1000 and UF membrane. Connect filter cartridge AIFIR1000 and UF membrane by First, connect tubing coming out of AIFIR1000 inlet with UF placing UF membrane into mounting clips, which are already membrane outlet connector. CAUTION! During the installed on the system mounting bracket.